Microdialysis based device for continuous extravascular monitoring of blood glucose

Feichtner, Franz and Schaller, Roland and Fercher, Andreas and Ratzer, Maria and Ellmerer, Martin and Plank, Johannes and Krause, Bernd and Pieber, Thomas and Schaupp, Lukas (2010) Microdialysis based device for continuous extravascular monitoring of blood glucose. Biomedical Microdevices, 12 (3). pp. 399-407.

Full text is not hosted in this archive but may be available via the Official URL, or by requesting a copy from the corresponding author.

Official URL: http://www.springerlink.com/content/y41374kq552822...

Abstract

Glycemic control of intensive care patients can be beneficial for this patient group but the continuous determination of their glucose concentration is challenging. Current continuous glucose monitoring systems based on the measurement of interstitial fluid glucose concentration struggle with sensitivity losses, resulting from biofouling or inflammation reactions. Their use as decision support systems for the therapeutic treatment is moreover hampered by physiological time delays as well as gradients in glucose concentration between plasma and interstitial fluid. To overcome these drawbacks, we developed and clinically evaluated a system based on microdialysis of whole blood. Venous blood is heparinised at the tip of a double lumen catheter and pumped through a membrane based micro-fluidic device where protein-free microdialysate samples are extracted. Glucose recovery as an indicator of long term stability was studied in vitro with heparinised bovine blood and remained highly stable for 72 h. Clinical performance was tested in a clinical trial in eight healthy volunteers undergoing an oral glucose tolerance test. Glucose concentrations of the new system and the reference method correlated at a level of 0.96 and their mean relative difference was 1.9 ± 11.2%. Clinical evaluation using Clark’s Error Grid analysis revealed that the obtained glucose concentrations were accurate and clinically acceptable in 99.6% of all cases. In conclusion, results of the technical and clinical evaluation suggest that the presented device delivers microdialysate samples suitable for accurate and long term stable continuous glucose monitoring in blood.

Item Type:Article
Uncontrolled Keywords:Microdialysis - Sampling - Glucose monitoring - Extravascular - In vitro study - Clinical trial
Subjects:Biomedical Science > Nanobiotechnology
Biomedical Science > Nanotechnology for human health
Biomedical Science > Nanomedicine
ID Code:8953
Deposited By:IoN
Deposited On:30 Apr 2010 16:02
Last Modified:30 Apr 2010 16:02

Repository Staff Only: item control page