Nano Archive

Immobilization of glucose oxidase on electrodeposited nickel oxide nanoparticles: Direct electron transfer and electrocatalytic activity

Salimi, Abdollah and Sharifi, Ensiyeh and Noorbakhsh, Abdollah and Soltanian, Saied (2007) Immobilization of glucose oxidase on electrodeposited nickel oxide nanoparticles: Direct electron transfer and electrocatalytic activity. BIOSENSORS & BIOELECTRONICS, 22 (12). pp. 3146-3153.

Full text is not hosted in this archive but may be available via the Official URL, or by requesting a copy from the corresponding author.

Official URL: http://www.sciencedirect.com/science?_ob=ArticleUR...

Abstract

For the first time glucose oxidase (GOx) was successfully co-deposited on nickel-oxide (NiO) nanoparticles at a glassy carbon electrode. In this paper we present a simple fabrication method of biosensor which can be easily operated without using any specific reagents. Cyclic voltammetry was used for electrodeposition of NiO nanoparticle and GOx immobilization. The direct electron transfer of immobilized GOx displays a pair of well defined and nearly reversible redox peaks with a formal potential (E0′) of −0.420 V in pH 7 phosphate buffer solution and the response shows a surface controlled electrode process. The surface coverage and heterogeneous electron transfer rate constant (ks) of GOx immobilized on NiO film glassy carbon electrode are 9.45 × 10−13 mol cm−2 and 25.2 ± 0.5 s−1, indicating the high enzyme loading ability of the NiO nanoparticles and great facilitation of the electron transfer between GOx and NiO nanoparticles. The biosensor shows excellent electrocatalytical response to the oxidation of glucose when ferrocenmethanol was used as an artificial redox mediator. Furthermore, the apparent Michaelis–Menten constant 2.7 mM, of GOx on the nickel oxide nanoparticles exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. In addition, this glucose biosensor shows fast amperometric response (3 s) with the sensitivity of 446.2 nA/mM, detection limit of 24 μM and wide concentration range of 30 μM to 5 mM. This biosensor also exhibits good stability, reproducibility and long life time.

Item Type:Article
Uncontrolled Keywords:glucose oxidase; direct electron transfer; nickel oxide nanoparticles; biosensor; glucose
Subjects:Material Science > Nanofabrication processes and tools
Analytical Science > Nanotechnology for sensing and actuating
Material Science > Bio materials
Material Science > Nanochemistry
ID Code:2599
Deposited By:Anuj Seth
Deposited On:27 May 2009 12:05
Last Modified:27 May 2009 12:05

Repository Staff Only: item control page